|
Problem / Question
|
|
The investment ring has cracks after burn-out
|
|
Cause (1)
|
| The ring has been left too long after investing. |
|
Solution / Answer (1)
|
|
If the ring has been left for more than 12hours after investing, soak the ring in the water for 3-5 minutes, and then place it in the preheated furnace at 850°C(1562°F)
|
|
Cause (2)
|
|
The mixing ratio of powder and liquid is wrong.
|
|
Solution / Answer (2)
|
| Observe the specified ratio (24ml/100g). |
|
Cause (3)
|
| Too much Vaseline has been applied to the ring, pedestal base and leveling cap. |
|
Solution / Answer (3)
|
| Use of Dry Teflon®-Silicone spray is recommended. Do not apply too much Vaseline more than is needed. Wipe extra Vaseline off with tissue paper. |
|
Cause (4)
|
| The specified press investment liquid has not been used. |
|
Solution / Answer (4)
|
| Use the specified liquid. |
|
Cause (5)
|
| Removing the investment ring from the ring former , pedestal base and leveling cap is too early. |
|
Solution / Answer (5)
|
| Remove the investment ring after the specified time lapse. |
|
Cause (6)
|
| Mixing of the powder and liquid is not sufficient. |
|
Solution / Answer (6)
|
| Mix the powder and liquid for one minute with a vacuum mixer. |
|
Problem / Question
|
|
The investment ring has cracks after pressing.
|
|
Cause (1)
|
| The plunger has not been inserted vertically. |
|
Solution / Answer (1)
|
|
Ensure that the plunger is inserted vertically.
|
|
Cause (2)
|
|
The wax patterns have not been positioned properly in the ring.
|
|
Solution / Answer (2)
|
| Secure the distance of at least 8 mm between the wax pattern and the ring inner wall, and the distance of at least 10mm from the ring top to the top of the wax pattern. |
|
Cause (3)
|
| The specified Noritake press investment has not been used, or water with liquid was used for mixing with Noritake press investment. |
|
Solution / Answer (3)
|
| Be sure to use Noritake press investment. Never use water for mixing. Be sure to use liquid only for mixing. |
|
Cause (4)
|
| Press time is too long. |
|
Solution / Answer (4)
|
| Observe the specified press time. |
|
Cause (5)
|
| The investment ring has been left too long after taken out from the burn-out furnace. |
|
Solution / Answer (5)
|
| After taking out the investment ring from the ring furnace, set the ring quickly to the press furnace. |
|
Cause (6)
|
| The top surface of the investment ring is not flat, or the top and the side of ring is not at 90 degrees angle. |
|
Solution / Answer (6)
|
| Ensure that the top surface is flat and the angle of top and the side of the ring is at 90 degrees. |
|
Cause (7)
|
| The investment ring has not been properly set in the press furnace. |
|
Solution / Answer (7)
|
| Place the investment vertically to the press furnace table and in the right position. |